Banner DUO-TOUCH SG Manual page 3

Two-hand-control safety kit
Hide thumbs Also See for DUO-TOUCH SG:
Table of Contents

Advertisement

®
DUO-TOUCH
SG –
A
S12
S11
13
23
A1
B
Power
13
Fault
C
In 1
In 2
14
D
Machine
Output
AT-FM-10K
Y2
14
24
S23
S21
E
Figure 1. DUO-TOUCH SG Safety Module
AT-FM-10K status indicators and
terminal locations
Key Legend:
A Power ON (green)
B Internal Fault (red)
C Input 1 Status (green)
D Input 2 Status (green)
E
Output Status (green)
WARNING
... Point-of-Operation Guarding
!
When properly installed, the DUO-TOUCH SG Two-Hand-Control Safety Module pro vides pro tec tion only for the hands of the
machine operator. It may be necessary to install additional point-of-operation safeguarding, such as safety light curtains and/or
hard guards, to protect per son nel from haz ard ous ma chin ery. Fail ure to install point-of-operation guards on haz ard ous ma chin-
ery can result in a dan ger ous con di tion which could lead to serious injury or death.
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Two-Hand-Control Kits with STB Touch Buttons
A DUO-TOUCH SG Two-Hand-Control Safety Module may be used with:
• 2 Banner STB Self-Checking Optical Touch Buttons, each with one normally open
and one normally closed relay output contact, or
• 2 Banner STB Self-Checking Optical Touch Buttons, each with two current-sourcing
PNP outputs, or
S13
Y1
• 2 mechanical push buttons with one normally open and one normally closed
23
contact each (Form C contact)
K1
If the machine operator removes one or both hands from the STB(s), the Duo-Touch
K2
SG relays de-energise, causing the output contacts to open. The relays will not re-
24
energise until both STBs are deactivated and then simultaneously reactivated.
Safety
A2
The Duo-Touch SG Two-Hand-Control Kit system is certified to:
S22
• Type IIIC requirements of EN 574/ISO 13851 Safety of Machinery – Two-Hand-
Control devices, and
• Category 4 requirements of EN 954-1/ISO 13849-1 Safety of Machinery – Safety-
Related Parts of Control Systems – Part 1: General Principles of Design
The Safety Module's output signal consists of two sets of redundant, forced-
guided (mecahnically linked) contacts (see Figure 5 page 9). Circuitry within the
Safety Module monitors these internal contacts and prevents an output signal from
occurring if a fault is detected. A feedback loop is offered for monitoring the status of
the machine control elements.
DUO-TOUCH SG Safety Module LED Indicators
Power On:
Fault:
Input 1 (2) Status:
Output Status:
DUO-TOUCH SG Safety Module Description
ON when power is applied
ON if simultaneity is not met or external wiring fault
Flashing when internal fault condition is detected
ON if touch button is activated
OFF when button is not activated
Flashing if external wiring fault is detected
ON if both relays (K1 and K2) are energised
Flashing if feedback error has occurred