Technical Data - Graco ProMix PD2K Repair Parts

Proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Technical Data

Positive Displacement
Proportioner
Maximum fluid working
pressure:
AC0500 and AC0502
Systems with
Low-Pressure Pumps
AC0500 and AC0502
Systems with
High-Pressure Pumps
AC1000 and AC1002 Air
Spray Systems
AC2000 and AC2002
Air-Assisted Spray
Systems
Maximum working air
pressure:
Air supply:
Air filter inlet size:
Air filtration for air logic
(user-supplied):
Air filtration for atomizing
air (user-supplied):
Mixing ratio range:
Fluids handled:
Viscosity range of fluid:
Fluid filtration
(user-supplied):
Maximum fluid flow:
Fluid outlet size:
External power supply
requirements:
Operating temperature
range:
Storage temperature
range:
Weight of base model
(approximate):
Sound data:
Wetted parts:
AC0500 and AC0502
AC1000, AC1002,
AC2000, and AC2002
332709D
U.S.
300 psi
1500 psi
300 psi
1500 psi
100 psi
85–100 psi
5 micron (minimum) filtration required; clean and dry air
30 micron (minimum) filtration required; clean and dry air
one or two component:
• solvent and waterborne paints
• polyurethanes
• epoxies
• acid catalyzed varnishes
• moisture sensitive isocyanates
800 cc/minute (depending on material viscosity)
90 - 250 Vac, 50/60 Hz, 7 amps maximum draw
15 amp maximum circuit breaker required
8 to 14 AWG power supply wire gauge
36 to 122°F
—4 to 158°F
195 lb
Pumps sold separately; see selected pump manual for wetted parts information.
17–4PH, 303, 304 SST, Tungsten carbide (with nickel binder),
perfluoroelastomer; PTFE, PPS, UHMWPE
10.5 MPa, 105 bar
10.5 MPa, 105 bar
0.6–0.7 MPa, 6.0–7.0 bar)
3/8 npt(f)
0.1:1 — 50:1, ±1%
20–5000 centipoise
100 mesh minimum
1/4 npt(m)
Less than 75 dB(A)
Technical Data
Metric
2.1 MPa, 21 bar
2.1 MPa, 21 bar
0.7 MPa, 7.0 bar
2 to 50°C
—20 to 70°C
88 kg
77

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac0500Ac0502Ac1000Ac1002Ac2000Ac2002

Table of Contents