Troubleshooting
Communication Errors
NOTE: In some error codes listed below, a # symbol is shown as the last digit. This symbol represents the applicable
component number, which can vary. The unit's display will show the applicable number as the last digit in the
code. For example, the CAC# code listed in this table will be displayed as CAC1 if the affected component is
color change board 1, CAC2 for board 2, and so on.
Code
Type
CA0X
Alarm
CAC#
Alarm
CADX
Alarm
CAGX
Alarm
CAG#
Alarm
CDC#
Alarm
CDDX
Alarm
24
Description
Problem
Comm. Error
System does not detect
ADM
the Advanced Display
Module (ADM).
Comm. Error
System does not detect
Color Change
the Color Change
#
Module #.
Comm. Error
System does not
Fluid Module
see the Enhanced
Fluid Control Module
(EFCM).
Comm. Error
System does not
Gateway
detect a CGM that was
registered as being
connected at power
up.
Comm. Error
System does not detect
Modbus
a Modbus CGM that
Gateway
was registered as
being connected at
power up.
Duplicate Color
System detects two or
Change #
more identical Color
Change Modules.
Duplicate Fluid
System sees two
Module
or more identical
Enhanced Fluid
Control Modules
EFCM).
Cause
This communication
error indicates that
the Network has lost
communication with
the Advanced Display
Module.
This communication
error indicates that
the network has lost
communication with
the Color Change
Module #.
This communication
error indicates that
the Network has lost
communication with
the EFCM.
The Modbus CGM
address dial was
changed while the
system was powered
up.
The Modbus CGM is
not connected/failed.
More than one Color
Change Module with
the same address
is connected in the
system .
More than one EFCM
is connected in the
system.
Solution
Check CAN cable
connecting ADM to the
EFCM.
Check CAN cable
connections to
the Color Change
Module # and any
interconnected
modules.
Check CAN cables
connecting ADM to the
EFCM. Replace Cable
or EFCM as necessary.
Unplug the Modbus
CGM from the CAN
network and re-plug
it back in so that it
re-registers with the
new address.
Check that the Modbus
CGM is properly
connected to the CAN
network and it's LEDs
indicate it is powered.
Check the system and
remove the extra color
change module.
Check the system
and remove the extra
EFCM.
332709D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac0500Ac0502Ac1000Ac1002Ac2000Ac2002