Servicing The Fluid Section - Graco ProMix PD2K Repair Parts

Proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Repair

Servicing the Fluid Section

Removing a Pump
1. Follow the steps in
2. Remove the screws (56) holding the cover (8)
to the front of the unit.
3. Disconnect the cable from the pump driver (101).
4. Disconnect the air lines from the dosing valves
(V).
5. Disconnect the fluid inlet and outlet lines from the
pump manifolds (IN, OUT).
6. Remove the screws (15) and pump bracket (7).
Figure 40 Installing a Pump
60
Before Servicing, page
7. Loosen the jam nuts holding the pump to the
mounting bracket (4). Remove the pump.
8. See manual 332339 to repair the pump.
Installing a Pump
1. Slide the pump into the mounting bracket (4).
Tighten the jam nuts to secure.
2. Install the pump bracket (7) and screws (15).
3. Connect the fluid inlet and outlet lines to the
48.
pump manifolds (IN, OUT).
4. Connect the air lines to the dosing valves (V).
5. Connect the cable to the pump driver (101).
6. Install the cover (8) to the front of the unit with
the screws (56).
7. Open the main air shutoff valve on the air supply
line.
8. Restore power to the unit. Turn on the power
switch at the electrical control box.
332709D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac0500Ac0502Ac1000Ac1002Ac2000Ac2002

Table of Contents