Advanced Options

Advanced options are available only to the
Admin user and consist of settings that are
related to specialist areas such as power
control and DDC.
To get here
1 From a local or remote keyboard, log on
as a standard (limited options) or 'admin'
user.
2 Press
(hotkeys can change).
3 Press
to select 'More menus'.
4 Press
again to select 'Advanced
menus'.
5 Select 'Setup Options'.
DDC Options
The options within this section are related to the Display Data Channel features
supported by the AdderView CATx 1000. DDC is an industry standard format
that allows computer systems to be informed of the capabilities of the video
monitor connected to them.
DDC Source
Settings: AUTO, LOCAL, REMOTE, DEFAULT
Determines which user port monitor should be interrogated to discover its
capabilities. AUTO begins with the local user port and if it fails, it then checks
the remote port and if that also fails to produce a result, it uses a set of default
values. The LOCAL and REMOTE settings force the unit to interrogate only
the local and remote monitors respectively, and DEFAULT uses only the pre-
programmed settings.
DDC Refresh
Settings: AT START, DISABLED
AT START sets the AdderView CATx 1000 to read DDC information from the
selected source at power up. When DISABLED, no new DDC data is sought and
existing information is used. When viewing this menu, press F7 to discover DDC
information from the chosen source immediately.
ADDERVIEW CATx 1000
Advanced Options
DDC Options
Power Control
USB Country Code
F1-More menus
Enter-Select
Esc-Quit
Firmware Version 1.01b06
Power Control
The options within this section are concerned
with the operation of the
POWER CONTROL
port when used to command optional system
power control units.
Baud Rate
Settings: 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200
Configures the communication speed of
the
port and must match
POWER CONTROL
the speed used by the connected power
switch(es). Note: The PSU-8MASTER and PSU-
8SLAVE power switches supplied by Adder
require a setting of 9600.
Format
Settings: NONE.8.1, ODD.8.1, EVEN.8.1, NONE.8.2, NONE.7.2, ODD.7.2,
EVEN.7.2
Configures the data format used by the serial port and must match the format
used by the connected power switch(es). The NONE/ODD/EVEN portion relates
to the parity checking; the 7/8 value is the size of the data byte and the 1/2
value determines the stop bit(s) used after each data byte.
ADDERVIEW CATx 1000
Power Control
Power Control
ENABLED
Baud Rate
9600
Format
NONE.8.1
Space-Toggle
-Up
-Down
Esc-Quit
continued