Global Preferences (continued)
OSD Dwell Time
Settings: 1, 2, 3, 5, 10 SECONDS
After a successful computer channel change the AdderView CATx 1000 will
display a confirmation message for a few seconds. The length of time that this
confirmation message dwells on the screen may be changed.
User Timeout
Settings: 1, 2, 5, 10, 30 SECONDS, 1, 5, 10 MINUTES
When both a local and remote user wish to use the system, only one can have
access at any one time. When no keyboard or mouse data has been received
from the active user port for the user timeout period, the AdderView CATx 1000
will allow the other user to access the computer. The new port then becomes
the active port until it too times out. To avoid confusion between users it is
desirable to set the timeout period to be sufficiently long so that user's work
is not needlessly interrupted by other users and sufficiently short to ensure
good overall system efficiency. The user timeout value also controls the timeout
between the local port and remote (extended) user port 1.