Remote user (via X100/X200 extender)

One user can be placed a maximum of 300
metres (980 feet) from the AdderView CATx
1000 unit. The remote user is connected via
an Adder X100 or X200 extender module and
suitable category 5, 5e or 6 cabling (with no
crossover).
Note: It is not possible to connect a remote
user while the unit is cascaded to another unit.
Cable lengths for remote user locations
The maximum length of cable between the remote user and the AdderView
CATx 1000 unit can be up to 300 metres (980 feet). However, bear in mind that
the overall distance between the remote user and any computer system must
not exceed 300 metres (980 feet).
Overall maximum length between the remote user and
any host system must not exceed 300 metres (980 feet)
REMOTE
X100
USER
300 metres (980 feet)
maximum
In situations where any computer system will be placed a significant distance
from the AdderView CATx 1000 unit, ensure that the distance to any remote
user is similarly less than 300 metres (980 feet).
To connect a remote user
1 Place an Adder X100 or X200 extender unit adjacent to the remote user
location.
2 Attach the video monitor,
keyboard, mouse, power adapter
(and speaker) connectors to the
sockets of the Adder
X100 or X200
module.
From mouse
From keyboard
From video monitor
LOCAL
REMOTE
USER
USER
X200
POWER
IN
CAM
COMPUTER
POWER
SYSTEM
SWITCH
COMPUTER
CAM
SYSTEM
10 metres
(32 feet)
maximum
Adder X00
module
3 Lay a suitable length of category 5, 5e or 6 cabling between the Adder
X100/X200 module and the AdderView CATx 1000 unit. Please refer to the
section Cable lengths for remote user locations opposite.
4 Attach the connector of the cable run to the socket of the Adder X100/X200.
Category , e or
 cable leading to
AdderView CATx 000
unit
From power adapter
5 At the other end of the cable run, attach the cable connector to the socket
on the front panel of the AdderView CATx 1000 unit.
K V
M
o n ly
Category , e or  cable
from Adder X00/X00
module
6 Where necessary, use the in-built video compensation feature of the Adder
X100/X200 module to eliminate any effects caused by the cable run.
Adder X00/X00
module
AdderView CATx 000
front panel