Switching Control Via The Options Port - ADDER CCS-PRO8 User Manual

Table of Contents

Advertisement

Switching control via the Options port

The
port allows an external serial input, typically from a computer, to control
OPTIONS
the selection of the various channels. You can use either an optional serial cable (part
number VSC40) or alternatively construct a custom cable to link the CCS-PRO switch
and the computer. For pin-out details of the custom cable, see
Upon receipt of the correct code, the CCS-PRO will switch immediately to the
appropriate channel.
Connecting a computer for remote control
The cable link from the computer needs to connect the transmit (TXD) line of the
computer to the receive (RXD) input of the CCS-PRO and also link the ground
terminals (GND) of the two devices. See
To connect a computer remote control
1 Use an optional serial cable to link the
PRO switch and a vacant serial port on the computer.
IMPORTANT: Do not
connect the OPTIONS
port to any network.
 Note: If the optional CCS-XB module is used with the CCS-PRO, connect the computer instead
to the
port on the CCS-XB module.
TO KEYPAD OR PC
Appendix
1.
Appendix 1
for details.
port on the rear panel of the CCS-
OPTIONS
Serial port parameter settings
Ensure that the chosen serial port is configured to the following:
• Baud rate:
1200
• Data bits:
8
• Stop bit:
1
• Parity:
None
Channel selection codes

ASCII
Character
Hex
Decimal
• Channel 1:
'1'
0x31
• Channel 2:
'2'
0x32
• Channel 3:
'3'
0x33
• Channel 4:
'4'
0x34
• Channel 5:
'5'
0x35
• Channel 6:
'6'
0x36
• Channel 7:
'7'
0x37
• Channel 8:
'8'
0x38
49
50
51
52
53
54
CCS-PRO8 models only
55
56
15