Cloning - Curtis Instruments MultiMode 1230 Manual

Ac induction motor controller
Table of Contents

Advertisement

3 — PROGRAMMABLE PARAMETERS:
ALLOWABLE
PARAMETER
Fault Code
44
Cloning Controllers
OTHER SYSTEM PARAMETERS MENU, cont'd
RANGE
/
Configures the status LED driver (J1 Pin 17) to display fault information in
OFF
ON
Fault Code format or Fault Category format:
On = Fault Code format
The status LED driver provides a pulsed signal equivalent to the fault
code flashed by the controller's built-in status LED; these codes are listed
in Table 3, page 54.
Off = Fault Category format
The status LED driver indicates three different categories of faults;
these categories are listed in Table 4, page 55.

CLONING

(for copying parameter settings to multiple controllers)
Once a controller has been programmed to the desired settings, these settings
can be transferred as a group to other controllers, thus creating a family of
"clone" controllers with identical settings. Note: Cloning only works between
controllers with the same model number and software version. For example,
the programmer can read all the information from a 1230-2101 controller and
write it to other 1230-2101 controllers; however, it cannot write that same
information to 1230-2102 controllers.
To perform cloning, plug the 13XX programmer into the controller that
has the desired settings. Scroll down to the Functions menu; "Clone" is the
only function included here. Select "Get Settings From Controller" to copy
the settings into the programmer.
Plug the programmer into the controller that you want to have these
same settings, and select "Write Settings To Controller."
DESCRIPTION
Curtis 1230 Manual,
Rev. C

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiMode 1230 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF