Analogue Value Display; Bipolar Signal Ranges - Festo CPX-AP-I-4AI-U-I-RTD-M12 Instructions & Operating

Analogue input module
Table of Contents

Advertisement

Analogue value display

6
Analogue value display
The analogue values of the input signals are always represented with 15 bits plus sign
è Tab. 9 Analogue value display.
There are different resolutions depending on the signal range.
Bit
15
14
13
12
14
13
12
Sign 2
2
2
MSB
Tab. 9 Analogue value display
VZ = sign (0 = positive value, 1 = negative value)
MSB = most significant bit
LSB = least significant bit
6.1

Bipolar signal ranges

Voltage measuring range –10 V ... +10 V
Signal range
–10 V ... +10 V
1)
 10.2 V
>
 10 V 
 10.2 V
...
>
10 V 
 +10 V
...
 
10 V 
 
10.2 V
...
<
 
10.2 V
<
1) 1 LSB (least significant bit) corresponds to 313 μV; resolution 16 bits
Tab. 10 Voltage measuring range –10 V... +10 V
Voltage measuring range –5 V ... +5 V
Signal range
–5 V ... +5 V
1)
 5.1 V
>
 5 V 
 5.1 V
...
>
5 V 
 +5 V
...
 
5 V 
 
5.1 V
...
<
 
5.1 V
<
1) 1 LSB (least significant bit) corresponds to 156 μV; resolution 16 bits
Tab. 11 Voltage measuring range –5 V... +5 V
Festo — CPX-AP-I-4AI-U-I-RTD-M12 — 2020-03
11
10
9
8
11
10
9
8
2
2
2
2
Digital values
decimal
 32640
>
32001 
 32640
...
32000 
 +32000
...
32001 
 
32640
...
 
32640
<
Digital values
decimal
 32640
>
32001 
 32640
...
32000 
 +32000
...
32001 
 
32640
...
 
32640
<
7
6
5
4
7
6
5
4
2
2
2
2
hexadecimal
 0x7F80
>
0x7D01 
 0x7F80
...
0x8300 
 0x7D00
...
0x82FF 
 0x807F
...
 0x807F
<
hexadecimal
 0x7F80
>
0x7D01 
 0x7F80
...
0x8300 
 0x7D00
...
0x82FF 
 0x807F
...
 0x807F
<
3
2
1
0
3
2
1
0
2
2
2
2
LSB
Range
Overflow
Overdrive range
Nominal range
Underdrive range
Underflow
Range
Overflow
Overdrive range
Nominal range
Underdrive range
Underflow
13

Hide quick links: