Champion 71001I EU Owner's Manual & Operating Instructions page 10

Portable inverter generator
Hide thumbs Also See for 71001I EU:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

OPERATION
Electric (Optional) and Recoil Start
1.
Make certain the generator is on a flat, level surface.
2.
Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
3.
Turn the fuel valve to the "On" position.
4.
Turn the battery switch to the "On" position.
5.
Push the Choke button in to the "Choke" position.
6.
Turn the ignition switch to the "On" position.
7.
ELECTRIC START: Press and hold the ignition
switch to the "START" position. Release as the
engine begins to roll over. If the engine fails to start
within five seconds, release the switch and wait at
least ten seconds before attempting to start the
engine again.
8.
RECOIL START: Pull the starter cord slowly until
resistance is felt and then pull rapidly.
9.
As engine warms up, push the choke button to the
"Run" position.
NOTE
Keep choke button in "Choke" position for only 1
pull of the recoil starter. After first pull, push choke
button to the "Run" position for up to the next 3
pulls of the recoil starter. Too much choke leads to
spark plug fouling/engine flooding due to the lack of
incoming air. This will cause the engine not to start.
10
Recoil Start - Alternate Model
1.
Make certain the generator is on a flat, level surface.
2.
Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
3.
Turn the fuel cap vent lever to the "On"position.
4.
Turn the fuel valve to the "On" position.
5.
Pull the Choke lever out when starting the generator.
6.
Turn the ignition switch to the "On" position.
7.
Pull the starter cord slowly until resistance is felt
and then pull rapidly.
8.
As engine warms up, push the choke button to the
"Run" position.
NOTE
If the engine starts but does not continue to run
make certain that the generator is on a flat, level
surface. The engine is equipped with a low oil
sensor that will prevent the engine from running
when the oil level falls below a critical threshold.