Through-beam sensor laser
Table of Contents

Advertisement

Available languages

Available languages

Setting of the sensitivity with moving objects
Activate the programming mode of the unit.
1
Press for about 2s until the red LED flashes.
The red LED goes out; the yellow and green LEDs flash alternately.
The unit is in the programming mode.
During the measurement (about 1s) allow at least two objects to
move through the detection area.
2
Press once.
The yellow and green LEDs go out for approx. 1s,
then flash again alternately.
During the measurement (about 1s) allow at least two objects to
move through the detection area.
3
Press once.
The yellow and green LEDs go out for approx. 1s,
after approx. 3s the green LED is on.
The unit is in the operating mode.
receiver
receiver
receiver
transmitter
transmitter
transmitter