Table 3-7. Coupling Port Information Table
Port
Port
Description
Outlets
No.
Size
1
2
-12
Steer/Axle Extend
(Tank)
2
2
-10
Steer/Axle Extend (Pres-
sure)
3
1
-10
Drive A
4
1
-10
Drive B
5
1
-10
Drive A
6
1
-10
Drive B
7
2
-12
Case Drain
3.26 GENERATOR
Every 250 hours
Every 250 hours of operation, check the drive belt for proper
tension.
1/2 in.
(13 mm)
3121142
Operating
Proof
Pressure
Pressure
PSI (Bar)
PSI (Bar)
250 (17)
375 (26)
3000 (207)
4500 (310)
3000 (207)
4500 (310)
3000 (207)
4500 (310)
3000 (207)
4500 (310)
3000 (207)
4500 (310)
250 (17)
375 (26)
SECTION 3 - CHASSIS & TURNTABLE
Every 500 hours
Every 500 hours of operation, service the generator brushes
and slip rings. Hostile environments may require more fre-
quent service.
Every 500 hours of service, blow out the inside of the genera-
tor. If operating in a hostile environment, clean monthly.