Partial Reset
The Partial reset provides a way to contact the TA7102i in a known and static state while
keeping most of the configuration unchanged.
Following a partial reset, the TA7102i management interface is set to the Rescue interface. The
default address for this interface is 192.168.0.1/24 and has its corresponding link-local IPv6
available and printed on the sticker under the TA7102i. Any existing network interface that
conflicts with the Rescue interface address is disabled.
You can contact the TA7102i at this address to access its configuration parameters. It is not
advised to access the unit on a regular basis through the Rescue network interface. You should
reconfigure the unit's network interfaces as soon as possible in order to access it through
another interface. See After a Partial Reset for more details.
In a partial reset, the following services and parameters are also affected:
4. AAA service: User(s) from profile are restored with their factory password.
SNMP service: Resets the enableSnmpV1, enableSnmpV2, enableSnmpV3 and snmpPort
values to their default values.
5. WEB service: Resets the serverPort to its default value.
6. To trigger the Partial Reset:
1. Insert a small, unbent paper clip into the RESET/DEFAULT hole located at the rear of the
TA7102i. While pressing the RESET/DEFAULT button, restart the unit. Do not depress
before all the LEDs start blinking (between 7-11 seconds).
2. Release the paper clip.
After a Partial Reset
Following a partial reset, you should:
1. Create or activate network interfaces as described in the Software Configuration Guide,
Chapter Interface Parameters, Section Interfaces Configuration. Do not disable the Rescue
interface!
2. Change the TA7102i system management network interface to something other than
Rescue as described in the Software Configuration Guide, Chapter Miscellaneous –
Management Interface, Section Management Interface Configuration. Note that you must be
able to contact the interface you select in order to continue with the following steps.
3. Contact the TA7102i through the new system management network interface.
4. Disable the Rescue network interface as described in the Software Configuration Guide,
Chapter Interface Parameters, Section Interfaces Configuration.