Aastra ATP-CNX-020 Installation And Setup Manual
Aastra ATP-CNX-020 Installation And Setup Manual

Aastra ATP-CNX-020 Installation And Setup Manual

Conference network switch release 1.2

Advertisement

Quick Links

ATP-CNX-020
Document Revision 01.06
Aastra CNX
Conference Network Switch
Release 1.2
July 2005
Aastra CNX
Conference Network Switch
Installation and Setup Guide

Advertisement

Table of Contents
loading

Summary of Contents for Aastra ATP-CNX-020

  • Page 1 ATP-CNX-020 Document Revision 01.06 Aastra CNX Conference Network Switch Release 1.2 July 2005 Aastra CNX Conference Network Switch Installation and Setup Guide...
  • Page 2 *Aastra, Aastra Telecom, and the Aastra Telecom corporate logo are registered trademarks of Aastra Technologies, Limited. Microsoft, Microsoft Windows, and Internet Explorer are trademarks of Microsoft Corporation. NFS, Sun, SunOS, Java, JavaHelp, Solaris, and Sun Microsystems are trademarks of Sun Microsystems, Inc. Ethernet is a registered trademark of Xerox Corporation, Inc.
  • Page 3: Table Of Contents

    Warranty, regulatory, safety, and copyright / licensing notices Warranty - Aastra Telecom, Inc..v Warranty Limitation ... v Regulatory information ... vi U.S.A. requirements ... vi Canadian requirements ... vii European requirements ... ix Safety warnings ... x General warnings ... x Lithium battery caution ...
  • Page 5: Warranty, Regulatory, Safety, And Copyright / Licensing Notices

    Warranty - Aastra Telecom, Inc. Aastra Telecom Inc. ("Aastra") warrants ("Warranty") to its customer that: (i) Aastra has good and marketable title to the Product at the time of delivery to its customer, free and clear of any and all security interests, liens, claims, charges or encumbrances;...
  • Page 6: Regulatory Information

    Do not attempt to repair or modify this equipment. All repairs must be performed by Aastra Telecom, or an authorized Aastra Telecom representative.
  • Page 7: Canadian Requirements

    Aastra Telecom recommends that you install an AC surge protector in the AC outlet to which the equipment is connected. This helps to prevent damage to the equipment caused by local lightning strikes or other electrical surges.
  • Page 8 ATTENTION: Les utilisateurs ne doivent pas procéder à ces raccordements, mais doivent plutôt faire appel aux pouvoirs de réglementation en cause ou à un électricien, selon le cas. viii ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06...
  • Page 9: European Requirements

    EC declaration of conformity This product conforms to the provisions of Council Directive’s EMC Directive (89/336/EEC), Low Voltage Directive (73/23/EEC), and R+TTE Directive (1999/5/EC). ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06...
  • Page 10: Safety Warnings

    Safety Certifications • cUL 950, NTRL/UL 1950, TUV EN 60 950 • Telecom Approvals • FCC Part 68, Industry Canada, CTR4 • EMI/RF • FCC Part 15 Class A, EN55022 Class A (CISPR), EN55024 ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06...
  • Page 11: Software Licensing And Copyright

    Copyrights or Software Licenses; the overall aggregation and distribution of these separate programs is protected as a collective work, Copyright © Aastra Telecom Inc. 2005. Use and distribution of the CNX product are deemed to be acceptance of the Software Licensing terms contained within the Aastra CNX Service Level Agreement.
  • Page 13: Welcome

    Integrates with existing office systems: connects to Private branch exchange (PBX) using ISDN PRI and IP PBXs using SIP or H.323 • Comprehensive security features • Cost-effective conferencing for small to medium-size enterprises ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 You have purchased a highly functional, cost-effective, Welcome xiii...
  • Page 14: What Is In The Aastra Cnx Shipping Package

    Aastra CNX unit CompactFlash card Rack mounting brackets with Phillips head screws page Power cable Technical documentation CD ROM ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 “Aastra CNX Installation and Console cable License Key: 996-555-1e9-f6 License Key: 996-555-1e9-f6 License Key: 996-555-1e9-f65-421-e85 License Key...
  • Page 15: Aastra Cnx

    Aastra CNX. References For information about configuring and using the Aastra CNX, see related documentation on the Aastra CNX Conference Network Switch Documentation ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 Aastra CNX...
  • Page 16: Preparing For The Hardware Installation

    If you are installing the Aastra CNX as a desktop unit, place it on a flat surface in close proximity to your PC, skip Step 2, and perform Steps 3 through 8. b. If you are installing the Aastra CNX as a rackmount unit, proceed to Step 2. ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06...
  • Page 17: Installing The Aastra Cnx In A Rack

    6 Phillips head screws. b. Align the bracket holes to the rack and insert truss-head screws (not provided). c. Tighten the screws to 15 in-lb (.69 Nm). ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 1 2 3 4 POWER ACTIVE...
  • Page 18: Connecting To The Console Port

    Console port parameters Parameter Value Baud rate 9600 Flow control None Data bits Stop bits Parity None PC or terminal Modem (AT or Hayes compatible) DB-25 RS-232 port PHONE DIAL (LEASE (LEASED) 3810 3810 ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06...
  • Page 19: Connecting The Network Cables

    Aastra CNX . Ethernet Connect the RJ-45 Ethernet UTP cable(s) to the RJ-45 10/100 ENET port(s) on the rear panel of the Aastra CNX. 100-240 1.0A 47-63HZ ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 T1 / E1 CONSOLE RESET Ethernet RJ-45 T1/E1 RJ-48C...
  • Page 20: Connecting The Ac Power Cable

    AC power cord T1 / E1 CONSOLE RESET Connect to a grounded 15 A power source (100 to 240 VAC). (North America: 120 V at 15 A) (Europe: 240 V at 10 A) ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 10/100 ENET...
  • Page 21: Starting Up And Checking The Aastra Cnx

    T1/E1 link. If the T1/E1 LEDs are ON Red, a Red alarm is present on the T1/E1 link. Contact your System Administrator. ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 Procedures 1 2 3 4...
  • Page 22: Configuring The Network Settings

    (1) Run network and time configuration The following procedure describes how to configure the network settings. Note: If at any time during the initial configuration process, you want to backout of the configuration, press <ESC> to cancel. ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06...
  • Page 23 The following displays: Netmask: Enter the Netmask for the Ethernet port for which you want to use as a management interface, and press <Enter>. For example: Netmask: 255.255.255.0 ↵ The following displays: Default Gateway: ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 Procedures (continued)
  • Page 24 “y” at step 8. The following message and prompt display (after entering “y” at the verification prompt): Configuring Domain Name Service (DNS)... Domain Name: cnx1 192.168.2.6 192.168.2.255 255.255.255.0 192.168.2.1 ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 (continued)
  • Page 25 The following message and prompts display: Before the following information is configured, please verify the information below is correct before proceeding. Domain Name: Nameserver #1: Nameserver #2: Is this correct (y/n): ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 aastra.com 192.167.2.11 192.168.2.12 Procedures (continued)
  • Page 26 Timezone: EST Are you sure? (y/n) Jamaica Navajo GMT+0 Japan GMT-0 Kwajalein GMT0 Libya Greenwich Hongkong MST7MDT Iceland Mexico Indian Mideast Iran Israel NZ-CHAT ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 PST8PDT Universal Pacific W-SU Poland Portugal Zulu Singapore Turkey (continued)
  • Page 27 Hour [19]: 14 Minutes [40]: The following displays: Before the following information is configured, please verify the information below is correct before proceeding. Date: 2005-03-09 14:40:00 Is this the correct time (y/n) [n]: ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06 Procedures (continued)
  • Page 28 Do you want to continue (y/n) [n]: Enter “y” to continue, and press <Enter>. The following prompts display: NTP Server #1: [pool.ntp.org]: NTP Server #2: [pool.ntp.org]: NTP Server #3: [pool.ntp.org]: NTP Server #4: [pool.ntp.org]: (continued) ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06...
  • Page 29 If you do not have your own NTP server, and the Aastra CNX has Internet connectivity, you may use the default server entry of pool.ntp.org. Aastra Telecom strongly recommends the use of NTP servers, either your own or the default servers. NTP servers avoid clock slippage and inconsistent conference start times on the Aastra CNX.
  • Page 30: Using The Aastra Cnx Gui Via The Web

    Aaster CNX Conference Network Switch Documentation CD. All documentation is provided in PDF format For troubleshooting If you are having problems using your Aastra CNX, contact your reseller or Aastra Telecom Technical Support. ATP-CNX-020 Rel. 1.2, Doc. Rev. 01.06...
  • Page 32 Aastra CNX Conference Network Switch Installation and Setup Guide Printed in the USA ATP-CNX-020 Aastra CNX Release 1.2, Document Revision 01.06 July 2005...

This manual is also suitable for:

Cnx

Table of Contents