House Installation; Displays, Warning Signals; Technical Specifications - GEV FMG 1350 User Manual

Radon detector
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
User manual

2.2.2 House installation

P1
Power connector (L)
OUT1 COM output (Neutral)
SIG1 Not wired

2.2.3 Displays, warning signals

Green power LED is flashing
Green power LED is on
Yellow error LED is lit,
continuous tone sounds
Red alarm LED is flashing,
warning tone interval sounds
ALL LEDs flash briefly.
A short warning tone sounds
2.3

Technical specifications

Connection
Power suppply
Standby current
Alarm current
Input power
Switch OUT1/OUT2
Installation height
Detector reach
Recommended lifetime
Protection level
optimal working space
Alarm threshold
Dimensions
Mains cable length
Mounting hole distance
Weight
16
BA_Radonmelder_001350.indd 16
80-230 V~
P1
P2
OUT2
SIG2
The device is in preparation status.
The device is ready for operation. Tension is on.
The device is not ready for operation.
The gas concentration is in the critical range.
The device is in self-test mode and enters the preparation
state after connection.
EURO mains cable
80-230 V~, 50/60 Hz (P1/P2)
≤ 100 mA
≤ 160 mA
≤ 3 W
ralais-powered
Gas is heavier than indoor air,
Example: liquefied petroleum
gas (LPG), radon:
0.3-1.0 m above the ground
max. 3 m
3 years
IP20
0 °C ~ +50 °C | <95 % Humidity; not condensing
10 000 ppm (10 % LEL)
115 x 72 x 45 mm
1.5 m
32 mm
165 g
COM NC/NO
SIG1 SIG2
P2
OUT1 OUT2
Power connector (N)
Signal / Conductor output NC / NO
Not wired
Gas is lighter than indoor air,
Example: natural gas, city gas:
0.3-1.0 m under the ceiling
26.03.2018 14:25:29