7
Connection
7.2.3.3
Other Systems for Saving Cooling Water
For information on additional possibilities for saving on cooling water, such as reuse of cooling water
for wetcleaning and washing machines, air-driven water recoolers, water recooling systems based on
refrigeration technology, etc., please contact our Sales Support department directly.
7.2.4

Cooling Water Outlet

The cooling water leaving the system can be directed to the sewer system, reused and recooled
because it circulates through the machine in a closed system and does not come into contact with
the solvent. You should endeavor to reuse the cooling water.
7.2.5

Compressed Air

The operating pressure is 6 bar (87 psi). The machine is equipped with a compressed air reducing
valve, pressure gauge and compressed air water separator. The line pressure should be 10 - 12 bar
(145 - 174 psi).
7.2.6

Process Water

Empty the process water collecting tank daily.
Dispose of the contents according to the regulations for your country.
7.2.7

Aeration Lines

Machine venting and aeration are done through a carbon filter cartridge.
27
7
P25/P30