5 Installation

5.1 Operating Environment

5.1.1

Regulations

You must observe applicable regulations for room ventilation and size, odor and
noise emissions, accident prevention, etc. The switch panel contains contacts for
the room ventilation control system (see Point 7.3.2).
Noise level:
62 dB (A)
(Average value at 6 measurement points at a distance of 2 m (78.7 in) from
the machine and 1.60 m (63.0 in) above the floor.
If there is an increase in the air-borne sound (for example, resonance) because of the spatial
conditions at the place of installation (for example, the condition of and distances between walls
and ceiling), you must take local sound insulation measures.
5.1.2

Temperature

Do not expose the machine to direct sunlight. Ensure that there is an adequate air supply for the heat
exchange (heat buildup.)
Room temperatures under 5 °C (41 °F) are not permitted because of the risk that the water in the
system will freeze.
During continuous operation, the room temperature is not permitted to exceed 40 °C (104 °F)
because of increased solvent consumption and for safety reasons.
Heat dissipated to the surroundings: *
Without Slimsorba
With Slimsorba **
*
2-bath procedure, precleaning bath low level for distillation
**
incl. desorption process per 25 cycles
5.1.3

Structural Surroundings

Partitions, panels, suspended ceilings and other structures near the machine must be installed in
such a way that they do not interfere with the operation, that no heat buildup occurs and that they
can be easily removed for maintenance and repair work.
10
kJ/h
kJ/h
5
5.1
P25-P30
15300
15500
P25/P30