SERVICING YOUR GENERATOR
Battery Removal
WARNING: Battery posts, terminals, and related accessories contain lead and
lead compounds. Wash your hands after handling.
1. Remove the four 6 mm flange bolts,
and remove the cover.
2. Remove the negative (–) cable from
the battery negative (–)
terminal first, and then remove the
positive (+) cable from the battery
positive (+) terminal.
3. Remove the flange nuts, and remove
the battery set plate.
4. Remove the battery from the battery
tray.
This symbol on the battery means that this product must not be
treated as household waste.
An improperly disposed of battery can be harmful to the environment and human
health.
Always confirm local regulations for battery disposal.
78
6 mm FLANGE BOLT (4)
NEGATIVE (–) CABLE
POSITIVE (+)
CABLE
BATTERY TRAY
COVER
BATTERY SET PLATE
FLANGE NUT