Control panel

For detailed information on the control panel, see ACx-AP-x assistant control panels user's
manual
(3AUA0000085685

Cleaning the control panel

Use a soft damp cloth to clean the control panel. Avoid harsh cleaners which could scratch
the display window.

Replacing the battery

The instructions below describe how to replace the battery that powers the real-time clock
of the control panel.
1. Turn the lid on the back of the control panel counter-clockwise until the lid opens.
2. Remove the battery gently.
3. Replace the battery with a new CR2032 battery. The battery holder has grip nails.
First slide the battery and then press on the other side. The battery will snap in.
4. Make sure that the battery polarity shows positive on the upside.
5. Put the lid back and tighten it by turning it clockwise.
6. Dispose of the old battery according to local disposal rules or applicable laws.

Memory unit

Replacing the memory unit

After replacing a control unit, you can keep the existing parameter settings by transferring
the memory unit from the defective control unit to the new control unit.
WARNING!
Do not remove or insert the memory unit when the control unit is powered.
1. Stop the drive and do the steps in section
you start the work.
2. Make sure that the control unit is not powered.
[English]).
Electrical safety precautions (page 35)
Maintenance 77