94 Technical data

Losses, cooling data and noise

ACS880-
607LC-...
Module
l
U
= 690 V
N
0870-7
1.6
1300-7
1.6
1730-7
3.2
2600-7
3.2
3900-7
4.8
5200-7
6.4
6500-7
8.0

Terminal and cable entry data for the resistor cables

These drawings show the terminal and cable entry dimensions for the resistor cables. The
dimensions are given in millimeters. Tightening torques depend on the bolt size and type.
See section
Tightening torques (page
Coolant volume
Cabinet
US gal
l
US gal
0.4
2.8
0.7
0.4
2.8
0.7
0.8
5.6
1.5
0.8
5.6
1.5
1.3
8.4
2.2
1.7
11.2
3.0
2.1
14.0
3.7
98).
Heat dis-
Coolant flow
sipation
US
l/min
kW
gal/min
16
4.2
3.3
16
4.2
5.1
32
8.5
6.5
32
8.5
10.1
48
12.7
15.1
64
16.9
20.1
80
21.1
25.2
Pres-
sure
Noise
loss
kPa
dB(A)
120
63
120
63
120
66
120
66
120
68
120
69
120
70