Festo PEV-1/4-B-M12 Operating Instructions Manual page 13

Pressure switch
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
PEV-1/4-B-M12
4
Fittting
Mechanical components
If neccessary:
S
Insert M5 fastening screws into the through holes 2.
Pneumatic components
S
Connect the PEV-... with an threaded connector (e.g. type CK-...) in the G ¼
supply port (tightening torque max. 20 Nm).
Electrical components
S
Use a connection socket as described in the section "Accessories."
S
Make sure that the cable is laid so that it
is:
– not squashed
– not bent
– not stretched
S Connect the PEV-... as shown in the following diagram.
Pin-no.
1
2
3
4
*)
When used with the connection socket type SIM-...
Fig. 5
he max. tightening torque of the union nut does not exceed 0.5 Nm (tighten
T
by hand).
Festo 0005NH– English
Connections
Cable colour
Switching voltage:
Brown
0...48 V AC/DC
Normally-closed out-
White
put
Not connected
---
Normally-open out-
Black
put
Fig. 4
*)
Pin assignment
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

192488

Table of Contents