Husqvarna 325iLK Workshop Manual page 24

Hide thumbs Also See for 325iLK:
Table of Contents

Advertisement

Symptom
The warning symbol on the user inter-
face flashes continuously.
The warning symbol on the user inter-
face flashes after start. The product
then stops.
The warning symbol on the user inter-
face flashes after start. The green
LED comes on but the product does
not start.
The product operates but there is no
indication light on the user interface.
The product starts immediately when
the battery is installed, without use of
the user interface.
The warning symbol on the user inter-
face shows a red light.
The product shows red light after in-
stalling a new control unit.
24 - Troubleshooting
Possible causes
The temperature is too high.
The temperature of the control unit or
the battery is too low.
The power trigger is caught in engag-
ed position.
The power trigger is pushed during
start.
Water in the main switch connector.
Short circuit in the user interface.
Short circuit in the main switch.
The signal between the battery and
the product is defective.
Defective connection in the user inter-
face connector.
The user interface is broken.
Short circuit in the user interface.
Permanent error codes prevent cor-
rect operation of the product.
The control unit is broken.
Spare part comes without software.
Recommended step
Wait for the product to become cool
(max. 5 min.).
Make sure that the product and the
battery are not colder than -10° C.
Disassemble the front handle and re-
move the dirt.
Do not push the power trigger when
you start the product.
Disassemble and dry the main switch
connector and then assemble it.
Replace the user interface.
Replace the main switch.
Make sure that the power connectors
between the battery and the product
are not dirty or damaged.
Make sure that the small cables be-
tween the connectors and the control
unit are not loose or damaged.
Do a check of the user interface func-
tion in the common service tool
(CST). Make sure that the user inter-
face connector is correctly assem-
bled, dry, not damaged and that there
is no corrosion.
Replace the user interface.
Replace the user interface.
Erase error codes in the common
service tool (CST).
Replace the control unit.
Use the common service tool (CST)
to install software.