3.4
During use
3.4.1
Low temperatures
Use "klar-pilot" anti-fog agent to prevent fogging of the visor.
3.4.2
High temperatures
Leave the danger zone immediately if there are any signs of damage,
e.g., bubbles in the visor.
3.4.3
Chemicals
Some substances can be absorbed by the material of the mask body
or may even diffuse through it. Further information can be obtained
from Dräger.
3.5
After use
WARNING
!
Do not doff the facepiece unless you are decontaminated and
in a safe environment.
Doff the facepiece as follows:
1. Remove canister, powered air-purifying respirator, self-contained
breathing apparatus, or air line breathing apparatus.
2. Pull the adjuster buckles of the neck straps forward with your
thumb and loosen the straps (see Figure F on Page 3).
3. Pull the facepiece away from your face over the head.
4. Dispose of the canister according to national guidelines.
Dräger X-plore 6000
4
4.1
The following details are manufacturer recommendations. Observe
national guidelines, too.
Type of work to be
performed
Visually check the facepiece
Clean and disinfect the
facepiece
Check correct function and
leak-tightness
Replace exhalation valve
disc
Replace speech diaphragm
and O-ring
1)
2)
(Use Instructions for NIOSH-approved full facepieces)
Maintenance

Maintenance table

X
valid for airtight packed facepieces, otherwise every 6 months
for airtight packed facepieces every 2 years
Maintenance
1)
X
X
2)
X
X
X
X
79