The Ucom Register Mapping List - Omron STC-HD203 Series Product Specifications And User's Manual

Color cmos camera
Table of Contents

Advertisement

7.4 The uCOM register mapping list

* Please do not change "Reserved data".
Address
7
6
5
000
X
X
X
001 -
X
X
X
00D
00E
X
X
X
00F
X
X
X
STC-HD203DV / STC-HD203DV-CS / STC-HD203SDI / STC-HD203SDI-CS
Product Specifications and Users Guide
4
3
2
1
0
Descriptions
X
X
X
User Preset
DSP register setting can save on eight Preset areas.
* When this vale saves to the EEPRM, camera starts with saved
DSP mode at power up.
0: Preset 0
2: Preset 2
4: Preset 4
6: Preset 6
X
X
Reserved
X
X
X
X
X
Reserved
X
Control by the "Push button" on the side of the camera
0: Disable
X
X
X
X
Reserved
X
X
UART baud rate
0: 9,600 bps
2: 38,400 bps
* Change to lower baud rate when communication error is
occurred.
X
X
X
Reserved
Return data and data length of UART write command
0: Return data is including exact same data of write command.
1: Return data is excluding data of write command, and data
length is 0.
UART check sum
0: Disable
* When selecting disable, camera process command even check
sum of send command is not mach.
1: Preset 1
3: Preset 3
5: Preset 5
7: Preset 7
1: Enable
1: 19,200 bps
3: 9,600 bps
1: Enable
No. 13S054-10
Default
0
-
1
-
2
-
0
1
38/78