automatically transfer to the next function code; while pressing PRG key is to abandon the current parameter
modification and directly return to the secondary menu of the current function code serial number.
Example: example of setting function code F3 - 02 to 15.00 Hz from 10.00 Hz
In the level III menu state, if the parameter does not flash, it indicates that the function code cannot be modified.
Possible reasons are:
This function code is an unmodified parameter, such as frequency inverter type, actual detection parameter,
operation record parameter, etc.
This function code cannot be modified in the running state. It can only be modified after shutdown.
3.5 Two quick search modes for function code parameters there
Are many function codes in this series. In order to facilitate quick search by users, the frequency inverter also
provides two quick search methods for function codes:
1) Selecting and customizing common function codes and users, up to 30 of which can be customized, to form a
user-defined code function code set; the user determines the function parameters to be displayed through the FE
group
2) Automatically arranges the function codes different from the factory values and the frequency inverters for
quick selection by the user;
This provides three function code lookup methods, the display code of each parameter display method is:
The display modes of the three function codes are switched by the quick key on the panel ( F0 - 43 is set to 11 ),
and the search or modification method after entering the function codes of each group is the same as that of the
previous keyboard operation:
3.6 Commissioning
The series of frequency inverters has three operation control modes, which including keyboard control, terminal
control and RS - 485 control. Its control can be selected by setting the function code F0 - 02.
Through keyboard operation, the function code F0 - 02 = 0, i.e. the panel start-stop control mode, presses the
run key on the keyboard, and the frequency inverter starts to run ( the run indicator lights up ); When the frequency
inverter is running, press the stop key on the keyboard to stop the frequency inverter ( the run indicator goes out )
3.7 Motor characteristic parameter setting and self - learning
When the frequency inverter operates in the "vector control" (F0 - 01 = 0 or 1) mode, it is highly dependent on
accurate motor parameters. This is one of the important differences from the "VF control" (F0 - 01 = 2) mode. In order
Parameter display mode
Function parameter mode
User - customized parameter method
The method for changing parameters by the users
18
Display
--F--
--U–
--C–