7 Functions of IO-Link I/O Hubs
Overview and Applications
This function records the time period during which the Unit/input power is supplied to the Digital I/O
Hub, and displays the period as the operating hours of the Hub.
Applicable Hubs
All models of the Digital I/O Hub
Function Details
The following shows the specifications of the monitoring total power-ON time.
Item
Measurement time
Measurement interval 10 minutes
Display unit
Default setting
Setting Method
There is no setting for this function.
Checking the Operating Hours
There are two ways to check the operating hours.
• Check from CX-ConfiguratorFDT
• Check through message communications from the Controller to the IO-Link device
 Checking from CX-ConfiguratorFDT
The following describes how to check from CX-ConfiguratorFDT. Refer to Setting IO-Link Devices
with the CX-ConfiguratorFDT in the NXR-series IO-Link Master Unit for EtherNet/IP User's Manual
(Cat. No. W619) for how to create a network configuration and how to go online.
1
Create a network configuration and then register the Digital I/O Hub.
2
Right-click the device DTM and select Go online.
The relevant device goes online. Devices in the Network View are displayed in bold while you
are online.
3
In the Configuration tab page, click Observation under Menu.
The Operating Hours indicates the operating hours of the Hub.
7-16
Specification
0 to 715,827,882 hours
1 hour (truncated to an integer)
0 hours
NXR-series IO-Link I/O Hub User's Manual (W620)