SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
7. In the HSD Load folder, double-click ADT_LOAD.exe to launch the load
application.
The EMS Loader opens in a DOS window, displays the Load Target menu, and
prompts you to select a target for the software.
8. To load control processor software to the control processor, press 0 (zero), and
then press ENTER.
The load application prompts you to type a filename.
9. Type the filename for the software being loaded to the HSD-Xi terminal control
processor, and then press ENTER.
The EMS Loader prompts you to select a COM port.
10. Type the COM port connected to the HSD-Xi terminal, and then press ENTER.
11. To start the load, press ENTER. To abort the software load, press ESC.
Communication with the HSD-Xi terminal is established. A percentage (%) load
status indicator appears on the screen. Once the load is complete, a confirmation
message briefly appears on the screen indicating that the file has been
successfully loaded. The DOS window closes, and the HSD-Xi terminal resets.
12. If no other software loads are required, go to "Verifying Software Loads" on page
5-7.
NOTE: If the load fails, restart the load from the beginning of the procedure. If,
after two attempts, the load still does not complete successfully, contact
EMS SATCOM Product Support for assistance.

(2) Updating Displayed Software Versions

Once you have uploaded the major software to the HSD-Xi terminal, you must load
a BIN file to display the new versions. Load this file according to the applicable
software service bulletin released by EMS SATCOM.
To update displayed software versions:
1. Remove power from the HSD-Xi terminal.
2. Connect a computer to the maintenance port of the HSD-Xi terminal.
3. Turn on the computer.
4. Save ADT_LOAD.exe to the same folder on your computer that contains the
software files.
It is recommended that you create a folder named HSD Load in the root directory
and save the load program file and the software files to this folder.
5. Apply power to the HSD-Xi terminal.
6. Close all other applications running on the computer. The load program will not
execute successfully if other programs are using the COM port.
7. In the HSD Load folder, double-click ADT_LOAD.exe to launch the load
application.
The EMS Loader opens in a DOS window, displays the Load Target menu, and
prompts you to select a target for the software.
23-15-30
5-6
8 MAY 09