You need the following hardware to install the HSD-Xi terminal:
size 1 ARINC 600 connector
size 1 coax contacts (on HSD-440 tray)—installation specific
size 5 coax contacts—installation specific
4.

Electrical Installation

A. Cabling Notes
The system transmit loss between the network mode HSD terminal and the HSD-Xi
terminal should be as close as possible to 29.5 dB. Figure 3-1 illustrates the System
Transmit (TX) loss.

Figure 3-1 HSD-Xi System Transmit (TX) Loss

23-15-30