C. Creating Connections
For information on creating SBB connections, see "Setting Up SBB" on page F-1, or the
eNfusion™ HSD High-speed Data Terminal Developer's Guide, MN-1252-13005.
6.

Configuring the system

After installing the HSD-Xi, you must configure the HSD to operate in network mode, and
set the HSD-Xi cable loss.
This section contains the following procedures:

Configuring the HSD Terminal for Network Mode

Enabling and Disabling the Classic Channel Card

A. Configuring the HSD Terminal for Network Mode
An ORT parameter in the HSD terminal defines the cable loss between the HSD terminal
and the HSD-Xi terminal. If the HSD-440 system configuration strapping is not set to
network mode, you can set the terminal category to network mode by following these
steps.
To configure the HSD terminal to operate in network mode, follow these steps.
1. Connect a computer to the maintenance port of the HSD terminal.
2. Open a VT100 compatible terminal running an emulator program (such as
HyperTerminal, ProComm Plus, or similar) and configure the serial port for ASCII,
19200 bps, 8 bits, Parity None, 1 Stop Bit, No Flow Control.
3. Log on to the HSD terminal using the password maint.
You can navigate through the HSD menus by pressing CRTL+N to scroll through the
menus.
4. Go to Menu 3 - M parameter 16 and select 2 =HW STRAPPED VALUE.
5. Go to Menu 3 - K parameter 48 Installed and select 1=Yes.
6. Reboot the HSD terminal and the HSD-Xi terminal.
B. Enabling and Disabling the Classic Channel Card
You can operate the network mode HSD system with or without operating the Classic
channel card in the HSD terminal. Note: This feature is available in Release
LI-1252-33374 A00.
To activate or deactivate the classic channel card of the network mode HSD terminal:
1. Connect a computer to the maintenance port of the network mode HSD terminal and
go to Menu 3. To navigate to Menu 3, press CTRL + N.
2. To set control processor parameters, press k.
A list of control processor parameters appears.
23-15-30
3-6
8 MAY 09