Hsd-Xi Input/Output Strapping; User Interfaces; Installing The Hsd-Xi And Escm; Hardware And Software Requirements - EMS eNfusion 1252-A-4100-01 System Description, Installation And Maintenance Manual

High-speed data terminal
Table of Contents

Advertisement

SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
F. HSD-Xi Input/Output Strapping
Table 3-1 provides the Input/Output (I/O) strapping for the HSD-Xi.
MP11A
1
1
1
1
0
0
0
0
NOTE: MP11D: Reserved, 0 = FWD Address Comm
G. User Interfaces
For the HSD-Xi terminal Ethernet interface, install an RJ-45 interface connector in the
cabin area. For the ISDN interface, install an RJ-45 interface connector in the cabin area.
5.

Installing the HSD-Xi and ESCM

Install the HSD-Xi and ESCM according to the System Interconnection diagrams,
Figure 3-7, Figure 3-8, Figure 3-9, and Figure 3-10.
Figure 3-4, Figure 3-5, and Figure 3-6 provide outline drawings for the HSD-Xi terminal
and ESCM. Mount the ESCM on a flat surface using four screws or bolts that fit the 0.125
inch holes in the mounting flange. You can install the ESCM a maximum of three meters
away from the HSD-Xi terminal.
A. Hardware and Software Requirements
You need a HSD-Xi terminal, 1252-A-4100, and an ESCM, 1252-A-4120, to use SBB
services.
You need the following software to use SBB services.
HSD-Xi, LI-1252-42001
HSD-440, LI-1252-33374
B. User Interfaces
You can access SBB services through the following interfaces:
Ethernet
ISDN

Table 3-1 HSD-Xi Input/Output Strapping

MP11B
MP11C
1
1
1
0
0
1
0
0
1
1
1
0
0
1
0
0
23-15-30
Input/Output Configuration
Invalid
Restricted (disable Data I/O)
MPDS (Future)1
SCPC (M4) only
Unrestricted (recommended if
there are no specific user
requirements)
Not Assigned
Not Assigned
Reserved
3-5