SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
7. Type the appropriate filename for the software being loaded to the HSD-Xi Channel
Card (for example appl41.hex or cfig41.hex), and then press ENTER.
The application prompts you to select a COM port.
8. Type the appropriate COM port (1 or 2—typically 1), and then press ENTER.
9. To start the load, press ENTER.
Communication with the HSD-Xi transceiver is established. A percentage (%)
progress indicator appears on the screen and shows the load status. Once the load
is complete, a confirmation message briefly appears on the screen indicating that the
file has been successfully loaded. The DOS window then closes, and the HSD resets
automatically.
D. Disconnecting Software Load Equipment
After you install the software and verify that the software loaded successfully, disconnect
your equipment properly from the HSD-Xi terminal.
To remove power and disconnect the HSD-Xi terminal properly:
1. Turn off the computer.
2. Disconnect the serial cable connector from the COM port.
3. Disconnect the cable connector from the HSD Maintenance Port.
E. Monitoring the HSD-Xi Terminal
Monitor the HSD-Xi terminal status by reading the maintenance port utility reports.
To activate a report:
1. Connect to the maintenance port utility of the HSD-Xi terminal.
2. To view a list of reports, press =.
3. To access a report, type the report number.
4. To activate the report, press esc.
The following reports provide useful information on the HSD-Xi terminal status.
Report 7—provides a log of call codes and events for every call made through the
HSD-Xi terminal.
Report 46—a comprehensive report that describes the overall health of the terminal
Report 78—provides transmit power values for components of the network mode HSD
system. NOTE: This report is not available on the HSD-Xi. HSD-Xi Transmit power
can be monitored in HSD-440 Report 78.
F. Software Load Procedure
EMS SATCOM may occasionally release new software for the HSD-Xi terminal.
CAUTION: DO NOT LOAD SOFTWARE INTO THE HSD-XI TERMINAL WHEN THE
TERMINAL IS FULLY INSTALLED IN THE AIRCRAFT.
CAUTION: MAKE SURE THAT ALL REPORTS AND MENUS ARE TURNED OFF.
23-15-30
5-3
8 MAY 09