Loading Control Process Software - EMS eNfusion 1252-A-4100-01 System Description, Installation And Maintenance Manual

High-speed data terminal
Table of Contents

Advertisement

SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
Swift64-PR-9140-x.x.x-rfcontrol.hex, ENTER, N, ENTER
NOTE: Do not load Swift64-PR-9140-x.xx-rfcontrol2.hex.
14. To terminate the list, press ENTER at the prompt.
Communication with the HSD-Xi terminal is established. A percentage (%) load
status indicator appears on the screen. Once the load is complete, a confirmation
message briefly appears on the screen indicating that the file has been
successfully loaded. The DOS window closes, and the HSD-Xi terminal resets.
15. Repeat steps 7 to 14 to load the software:
SwiftSBB_PR_9140_x_x_x-Config.hex, and:
SwiftSBB_PR_9140_x_x_x-cpumain.hex, ENTER, N, ENTER
SwiftSBB_PR_9140_x_x_x-CPUSwiftBB.hex, ENTER, N, ENTER
SwiftSBB_PR_9140_x_x_x-Modem.hex, ENTER, N, ENTER
SwiftSBB_PR_9140_x_x_x-ReleaseMarker.hex, ENTER, N, ENTER
SwiftSBB_PR_9140_x_x_x-VoiceCodec.hex, ENTER, N, ENTER
NOTE: Do not load SwiftSBB_PR_9140_x_x_x-RFControl.hex.
16. If no other software loads are required, proceed to "Verifying Software Loads" on
page 5-7.
NOTE: If the load fails, restart the load from the beginning of the procedure. If,
after two attempts, the load still does not complete successfully, contact
EMS SATCOM Product Support for assistance.

(1) Loading Control Process Software

This section describes how to load control processor software on to terminals.
CAUTION: SOFTWARE MUST NOT BE LOADED TO THE HSD-Xi TERMINAL
WHEN THE TERMINAL IS FULLY INSTALLED IN THE AIRCRAFT.
To load control processor software to the HSD-Xi terminal:
1. Remove power from the HSD-Xi terminal.
2. Connect a computer to the maintenance port of the HSD-Xi terminal.
3. Turn on the computer.
4. Save ADT_LOAD.exe to the same folder on your computer that contains the
software files.
EMS SATCOM recommends that you create a folder named HSD Load in the
root directory and save the load program file and the software files to this folder.
5. Apply power to HSD-Xi terminal.
6. Close all other applications running on the computer. The load program will not
execute successfully if other programs are using the COM port.