SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
5. To access the HSD-Xi parameter, type 48.
A prompt to define the HSD-Xi as installed or not installed appears.
6. To activate the connection between the network mode HSD terminal and the HSD-Xi
terminal, press 1.
7. Power cycle both units. The network mode HSD terminal can now communicate with
the HSD-Xi terminal.
To verify the HSD-Xi installation:
1. Connect to the maintenance port utility of the HSD-Xi terminal.
2. To navigate to Menu 4, press CTRL + N.
3. To verify the Forward ID of the terminals in the HSD-Xi, press q.
The forward ID for CC #1 appears.
4. To verify the system configuration and I/O strapping, press =, type 13, press ENTER,
and then press esc.
Report 13 is activated and displays the system configuration and data I/O strapping.
5. To navigate to Menu 3, press CTRL + O.
6. To verify LES access codes, press O.
The LES access codes appear.
7. To verify that the network mode HSD system recognizes the HSD-Xi terminal, press
=, type 78, press ENTER, and then press esc.
Report 78 is activated and displays information about the connected HSD-Xi terminal.
To Verify that the Network mode HSD terminal is operating correctly:
1. Connect a computer to the maintenance port utility of the network mode HSD terminal.
2. To verify receive C/No (Rx) signals, press =, type 69, press ENTER, and then press
esc.
Report 69 is activated and displays the receive C/No signal values for each channel
card in the network system. Make sure that receive C/No signal values are greater
than 50 dB/Hz.
3. To verify transmit (Tx) signals, press =, type 69 and press ENTER to disable report
69, then press =, type 78, press ENTER, and then press esc.
Report 78 is activated and displays transmit EIRP/Watt values for components of the
network system.
4. To verify that the network mode HSD is operating correctly, place a Swift64 call on
the HSD-Xi terminal, and make sure that EIRP/Watt values are between 14.5 dBW
and 22.5 dBW.
If the network mode HSD system does not pass these installation tests, refer to the
Testing and Fault Isolation section of HSD-440 System Description, Installation, and
Maintenance Manual, MN-1252-33077.
23-15-30
4-2
8 MAY 09