Ctm Piston Rebuild; Valve Removal And Disassembly - Culligan CTM Series Installation, Operation, And Service Instructions With Parts Lists

Culligan top mount water softeners
Table of Contents

Advertisement

CTM Piston Rebuild (Refer to

Valve Removal and Disassembly

1.
Having bypassed and depressurized
valve (PRV), vacuum breaker, drain adapter and plumbing adapter.
2.
Separate the plumbing at the unions, if necessary to remove the plumbing adapter from the valve.
3.
Disconnect the tubing from the pilot valve at the inlet and drain ports on the valve.
4.
Disconnect the wiring and remove the GBE controller by removing the two mounting screws, if using a front or
side mount bracket.
5.
Remove the tank adapter clamp by loosening the bolts on both sides and lift the valve body from the tank. (see
Figure 70 on page
6.
Remove 16 #3 screws from the top manifold, including the two under the enclosure, then remove the top mani-
fold by prying at the pry points. (see Figure 57)
Cat. No. 01029401
page 84
(page
50) the system, disconnect from the valve; the pressure relief
58)
Top Manifold Pry Points
Figure 57.
for Kit Options)