Installation instructions, for professionals only

4.8. Electrical connection

1. Unscrew the screws 3 with a screwdriver.
2. Remove the cover plates 1 and 2.
Fig. 10 Removing the cover plates
2
3
Connecting the Concept R mini combi 3.5 kW, 4.5 kW, 6.0 kW and 7.5 kW
(CP-RMC-35 / CP-RMC-45 / CR-RMC-60 / CP-RMC-75)
1. Guide the connection cable for the heating sys-
tem through the feed-through 4.
2. Connect the wires of the connection cable to
the matching terminals of the sauna heater,
depending on the type of connection, and to
the matching control device terminals. Observe
the installation instructions for the sauna control
and the connection diagrams on page 16.
p. 19/34
1
3
U
V
W
N
N
N
PE
4
EN