Mechanical Mounting - Motor Assembly; Flange Assembly; Preparation - Bosch Rexroth MKE E Series Project Planning Manual

Synchronous motors for potentially explosive areas
Table of Contents

Advertisement

DOK-MOTOR*-MKE*GEN2***-PR06-EN-P
Rexroth MKE Synchronous Motors for Potentially Explosive Areas acc. to ATEX and UL/CSA
12.3
Mechanical Mounting – Motor Assembly
12.3.1

Flange Assembly

12.3.2

Preparation

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
To attach the motors properly and safely to the machine, Rexroth recom‐
mends the following screws and washers for attachment.
The screwed connections must be able to take up both the force
due to the weight of the motor and the forces acting during opera‐
tion.
In the standard case, use cylinder screws DIN 912 - M... x ... - 8.8 and corre‐
sponding shimmings according to DIN EN 28738. Some motors do not need
any shimmings. See table.
If the screws and washers used do not comply with this recomm‐
dation, the stability class of the screws and the hardness class
must be equivalent in order to transmit the required tightening tor‐
ques (see
Fig.
MKE motors are designed for flange assembly (B05). Details on the mounting
holes are given in the corresponding dimension sheet. In general, the follow‐
ing assignment is applicable for attaching the motors:
Hole
Motor
Ø [mm]
MKE037
4.5
MKE047
6.6
MKE098
11.0
MKE118
14.0
M
Tightening torque in Newton meters
GA
1)
The indicated screw lengths apply for screwing into steel.
Fig.12-1:
Fastening accessory for flange mounting
Prepare the motor assembly as follows:
1. Procure tools, supplies, measuring and test equipment.
2. Check all components for visible damage. Damaged components may
not be mounted.
3. Ensure that dimensions and tolerances on the system side are suitable
for motor attachment (for details, see the dimension sheet).
4. Inspect all components, mounting surfaces and threads to ensure they
are clean.
5. Make sure that the assembly can be carried out in a dry and dust-free
environment.
6. Make sure that the holder for the motor flange is deburred.
Bosch Rexroth AG
12-1).
B05 (flange assembly)
Screw (8.8)
M
Type
1)
GA
M4×20
M6×20
M10×30
M12×40
107/135
Installation
Wash‐
er DIN EN 287
38
[Nm]
Ø [mm]
3.1
not necessary
10.4
not necessary
51
12
87
14

Advertisement

Table of Contents
loading

This manual is also suitable for: