9. TECHNICAL PARAMETERS
Inverter Models Only
Parameter
Max intended pool volume gallons (liters)
Operating air temperature
Performance Condition: Air 80°F (27°C), Water 80°F (27°C), Humidity 80%
Heating capacity (BTUH)
Heating capacity (BTUH) in silent mode
COP
Performance Condition: Air 80°F (27°C), Water 80°F (27°C), Humidity 63%
Heating capacity (BTUH)
Heating capacity (BTUH) in silent mode
COP
Performance Condition: Air 50°F (10°C), Water 80°F (27°C), Humidity 63%
Heating capacity (BTUH)
Heating capacity (BTUH) in silent mode
COP
Rated input power (kW)
Rated input current (A)
Power supply
Refrigerant (R410A) in oz.
Advised water flux GPM (L/min)
Sound pressure 39" (3 m) dBA
Heat exchanger
Casing
Air discharge
Water pipe in-out Spec inches
Net Dimension LxWxH inches (mm)
Net Weight lbs (kg)
* The values indicated are valid under ideal conditions: Pool is well covered, filtration system running at least 15 hours a day.
* The final specs will be in accordance with the specs of the product
22
30-I
2113
(8000)
30,000
24,000
10.0~5.8
28,500
22,800
9.0~5.4
18,300
14,600
4.4~4.0
0.2~1.5
0.86~6.52
28.2
13.2~17.7
(50~67)
33.4~45.2
34x14.1x25.5
(864x359x648)
222.7
(101)
Table J.
Technical Parameters - Inverter Models Only
Crosswind Inverter Models
40-I
50-I
2906
3698
(11000)
(14000)
32~109°F (0~43°C)
40,000
50,000
32,000
40,000
10.3~6.0
10.6~5.98
38,255
47,500
31,000
37,200
9.1~5.86
9.7~5.5
24,500
28,900
15,000
20,295
4.5~4.0
5.1~4.15
0.23~1.95
0.28~2.45
1~8.48
1.22~10.65
208-230VAC/ 1 Ph/60Hz
31.7
38.8
17.7~26.4
21.9~30.6
(67~100)
(83~116)
33.6~45.5
34.9~45.0
Titanium in PVC
ABS casing
Horizontal
1-1/2
37.8x13.7x25.9
37.8x13.7x25.9
(961x348x648)
(961x348x658)
277.8
330.7
(126)
(150)
65-I
4755
(18000)
65,000
52,000
11.2~5.61
56,000
44,800
9.9~5.35
37,000
26,970
5.2~4.3
0.34~3.4
1.48~14.78
45.9
28.5~37.5
(108~142)
38.2~49.3
37.8x15.4x25.9
(961x390x658)
379.2
(172)