FAN0046/0048/0053 Wall Fan and Kits
Thank you for selecting our Manrose 100mm Wall/Ceiling Fan.
Please read all instructions before commencing installation.
NOTE: (i) The fan is to be installed so that the blades are more than 2.1m above the floor. For
best results this Extractor Fan should be fitted as high on the wall as possible, or if
preferred, on the ceiling.
(ii) Do not install the unit within a shower cubicle. Use our shower fan SF125 models
(iii) Switch off mains supply before making electrical connections. This system should
be installed by a qualified electrician.
(iv) This fan is double insulated and does not require an earth.
(v) When installing fan through an external wall, an external wall grille must be fitted
at all times.
1.
C ut a 112mm min. diameter hole in the wall. If the fan is to be fixed onto the ceiling
ensure that the hole is between the joists.
2.
Fit 100mm (internal diameter) ducting flush to the plaster.
3.
Remove the cover from the fan by simply unclipping the fascia. The front cover screw
and plug are conveniently located within the fan housing as shown in diagram 1 & 2.
4.
Hold the body of the fan against the wall or ceiling and mark the four screw holes
and the cable entry. IMPORTANT: Ensure that the fan is square on the wall or ceiling.
5.
Bring power cable into position, as marked. Allow an extra 230mm (9") protruding to
facilitate connection.
6.
If an XP100 kit - Select a suitable position on the outside wall for the weatherproof
cowl. Carefully remove the cowl from its housing by levering gently at the sides with
a small screwdriver. Cut a 115mm hole ensuring first that the area is free from
obstruction.
Wiring of Standard Model FAN0046. (see Diagram 1).
7.
The fan can be connected to the light switch so that the fan will start when the light is
switched on. The fan should not be accessible to a person using either the shower or
the bath.
NOTE: All wiring must be fixed securely and the cable to the fan should be a
2
minimum of 1mm
in section. All wiring must comply with current Regulations.
This system must be installed by a qualified electrician.