Figure 22: Permissible installation
position of exhaust pipe end
WARNING
If the exhaust pipe ends is other than as shown in the Figure 22 it will pose a fire risk.

8.6.6 Electrical connections

8.6.6.1 Heater connection, control element
The electrical connection is to be made as
shown in the appropriate wiring diagram (see
Chapter 7). To connect the wiring harness,
remove the cover (see 9.2.1.1) on the heater
and connect the wiring harness plug to the
control unit.
Before using the heater for the first time fit the
cover to prevent the escape of hot air (heater
overheating). The wiring harness can be routed
either to the left or right from the heater.
8.6.6.2 Supply voltage connection
Ideally from the vehicle's central electrical system.
An additional blade terminal fuse holder is to be fitted to protect the heater (supplied with the heater). The fuse
holder may only be installed in the interior of the vehicle.
8.6.6.3 Rheostat connection
The wiring harness is prepared for connection to the rotary selector. Simply pull on connector housing to unplug
the connector (see Figure 26).
Air Top Evo 40 / Air Top Evo 55 Service Manual
Figure 23: Remove the fastening plate on the fuse
holder

Figure 24: Fuse Holder, installation position