Location Requirements; Electrical Requirements - Whirlpool ACE082XP1 Use And Care Manual

Whirlpool air conditioner use & care guide
Table of Contents

Advertisement

Available languages

Available languages

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Check the location where air conditioner will be installed. Proper
installation is your responsibility. Make sure you have everything
necessary for correct installation.
The location should provide:
Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air to rooms to be cooled.
A large enough opening for the air conditioner.
Adequate wall support for weight of air conditioner. Air
conditioner weighs between 80 and 110 lb (36.3 to 49.9 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
A
A. Cabinet louvers
Window installation (on some models)
Window opening measurements:
Width: 28" (71.1 cm) minimum to 40" (101.6 cm) maximum.
Height: 16 " (41.3 cm) minimum.
A. 28" (71.1 cm) minimum to 40" (101.6 cm) maximum
B. 16 " (41.3 cm) minimum
4
A
B
Through-the-wall installation
The wall opening measurements should be:
Height: 16" (40.6 cm) plus twice the thickness of wood used
to build frame.
Width: 22 " (57.5 cm) plus twice the thickness of wood used
to build frame.
A
A. 16" (40.6 cm) + 2 x C
B. 22 " (57.5 cm) + 2 x C

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located behind the front panel on the front flange above
the coil area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord
plug outlet
C
B
C
Wiring requirements
115 volt (103.5 min. -
126.5 max.)
0-12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.

Advertisement

Table of Contents
loading

Table of Contents