Banner E-Stop ES-TN-14H5 Instruction Manual page 7

Safety modules with adjustable delay
Table of Contents

Advertisement

E-Stop Safety Modules with Adjustable Delay –
+V
Emergency Stop Switch
*(Jumper on
S21-S22
for 1-channel
E-Stop)
(See WARNING)
Cancel Delay Input
L1
Machine
Control
Circuits
Non-safety Auxiliary
Monitor Contacts
Figure 3. E-Stop Safety Modules ES-TN-14H5 and -14H6 hookups
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
dc common
24V dc
ES-TN-14H5
A2
A1
ES-TN-14H6
X1
S11
X2
S21
MSC1
X3
S22
MSC3
X4
S12
MSC2
X5
Y1
MSC4
X6
Y2
Machine Master
Stop Control
4A max.
Elements
K1
K2
A
A
13
14
MSC1
Immediate
***
4A max.
K1
K2
B
B
23
24
MSC2
Immediate
4A max.
***
K1
K2
C
C
33
34
Immediate
4A max.
K1
K2
D
D
43
44
Immediate
4A max.
K3
K4
A
A
MSC3
57
58
Delayed
***
4A max.
K3
K4
B
B
MSC4
67
68
Delayed
4A max.
***
K3
K4
C
C
77
78
Delayed
4A max.
K3
K4
D
D
87
88
Delayed
K1
E
91
92
K2
E
Immediate
K3
E
01
02
K4
E
Delayed
Reset
Switch**
(jumper for Auto Reset -
see Warning on page 9)*
MSC-Monitor Contacts
(jumper if no feedback
contacts are monitored)*
MSC-Monitor Contacts
(jumper if 1 channel feedback
is selected or no feedback)*
L2
* See page 11 for DIP-switch configuration.
** The Safety Module can not be reset until the delay output
times out and switches, or until the Cancel Delay Input is
exercised. Attempting to reset the module (Manual Reset
mode) or re-arming the E-stop button (Auto Reset mode)
before the time-out occurs will result in a lockout (see
page 14 for instructions for clearing lockouts).
*** Arc suppressors (see WARNING).
Models ES-TN-14H5/-14H6
WARNING . . .
MSC1 MSC3
!
S33
Wiring of Arc Suppressors
If arc suppressors are
used, they MUST be installed as
shown across the actuator coil of
the Master Stop Control elements
(MSC1 to MSC4). NEVER install
suppressors directly across the
output contacts of the E-Stop
Safety Module. It is possible for
suppressors to fail as a short circuit.
If installed directly across the output
contacts of the Safety Module, a
short-circuited suppressor will
create an unsafe condition which
could result in serious injury or
death.
WARNING . . .
!
Interfacing MSCs
NEVER wire an
intermediate device (e.g., PLC, PES,
PC) between E-Stop Safety Module
outputs and the Master Stop Control
Element it switches, in such a manner
that:
• In the event of a failure there is a loss
of the safety stop command, or,
• The safety function can be
suspended, overridden, or defeated,
unless accomplished with the same
or greater degree of safety.
Whenever forced-guided, mechanically
linked relays are added as intermediate
switching devices, a normally closed
forced-guided monitor contact from
each relay must be added to the
series feedback loop between Safety
Module terminals X3 and X4 or X5
and X6.