5.3. SWITCH

M1 Terminal
(6)
M2 terminal of Lead
wire (black)
(6)
M1 terminal of Lead
wire (red)
OK
60 to 90°
Rear side view
M1 terminal of Lead
wire (red)
Figure 43
25 to 30°
M2 Terminal
Figure 44
NOK
Figure 45
M1 terminal of Lead
wire (red)
Figure 46
1. Connect M1 terminal of Lead wire (red) to Switch (6)
vertically.
2. Connect M2 terminal of Lead wire (black) to Switch (6)
with it tilted at 25 to 30° to the vertical as shown in the
figure on the left.
3. M1 terminal must be connected to Switch as shown in the
figure on the left.
4. Bend M1 terminal of Lead wire (red) at the range of
60° to 90° as shown in the figure on the left.