Operation Mode - Omron S8VS Series Manual

Switch mode power supply
Hide thumbs Also See for S8VS Series:
Table of Contents

Advertisement

S8VS
Mode Change (S8VS-@@@24A@@/S8VS-@@@24B@@/S8VS-@@@24BE@ Only)
S8VS-@@@24A@@ models (with display monitor) can display the output voltage, output current, peak hold current, or maintenance forecast
monitor time. S8VS-@@@24B@@/S8VS-@@@24BE@ models (with display monitor) can display the output voltage, output current, peak hold
current, or total run time.
Power-ON

Operation mode

Press and hold
U
D
Up key
or Down Key
for three seconds or more.
Setting mode
Note: No setting mode is provided for the S8VS-06024@.
Operation Mode
Various states of the Power Supply are indicated.
Models with Maintenance Forecast Monitor (S8VS-@@@24A@@)
Maintenance forecast monitor
Note: 1. The peak hold current starts measuring the current 3 seconds after the Power Supply is started. Inrush current is thus not measured.
2. For the factory setting, the output voltage will be displayed when the power supply is first turned ON. Thereafter, the output voltage will
be indicated in the same display when shutting down.
Setting Mode (Except for S8VS-06024@)
Set various parameters of the Power Supply.
Models with Maintenance Forecast Monitor (S8VS-@@@24A@@)
Operation Mode
or
Press 3 seconds
or more.
Undervoltage
detected
Maintenance
forecast
Note: 1. Press and hold the (9) Up Key U or (10) Down Key D for two seconds or more to increase or decrease the value rapidly.
2. The S8VS-06024@ is not provided with the setting mode and its parameters are fixed at the shipment setting.
18
Model indication
Press Mode key
and
hold for three seconds or more.
Or no key operation for 30 seconds or more.
Output voltage
(Voltage output by Power Supply is
monitored and displayed.)
Output current
(Current output by Power Supply is
monitored and displayed.)
Peak hold current (See note 1.)
(Maximum current output by Power Supply is
recorded and displayed.)
Press 3 seconds or more or no key
pressed for 30 seconds or more.
*
/
18.5 to
20.0
0.1-V steps
*
/
0.0 to
0.5
0.5-year steps
* Factory settings are in reverse
type.
Models with Total Run Time Monitor (S8VS-@@@24B@@/
S8VS-@@@24BE@)
Models with Total Run Time Monitor (S8VS-@@@24B@@/S8VS-@@@24BE@)
Operation Mode
o r
Press 3 seconds
or more.
Undervoltage
to 27.5 (V)
detected
Total run
to 5.0 (y)
time
Output voltage
(Voltage output by Power Supply is
monitored and displayed.)
Output current
(Current output by Power Supply is
monitored and displayed.)
Peak hold current
(Maximum current output by Power Supply is
recorded and displayed.)
Total run time monitor
Press 3 seconds or more or no key
pressed for 30 seconds or more.
*
/
18.5 to
20.0
to 27.5 (V)
0.1-V steps
*
/
to 150 ( × 1000 h)
1 to
50
1,000-hour steps
* Factory settings are in
reverse type.