Download Print this page
Antunes GST-1H Instructions

Antunes GST-1H Instructions

Belt replacement
Hide thumbs Also See for GST-1H:

Advertisement

Quick Links

ANTUNES www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
GST BELT REPLACEMENT INSTRUCTIONS (P/N 1012999)
WARNING
Turn the unit off, unplug the power cord and allow the
unit to cool down before performing any service or
maintenance on the unit.
General
If you experience any problems with these instructions, con-
tact the factory Technical Service Department at 630-784-1000
or toll free in the U.S. at 877-392-7854.
AFFECTED PRODUCTS: GST-1H
PARTS INCLUDED
Main Belt Replacement Kit
1 Pack: P/N 7001766
2 Pack: P/N 7001659
Instruction Sheet: P/N 1012999
TOOLS: Heat Resistant Gloves, Flat Head Screw Driver,
Clean Sanitized Towel and Approved Sanitizer
Belt Removal:
1. Press and release the Power button to turn the unit
off. The Tortilla Warmer enters a cool-down mode.
Wait until the unit automatically shuts down and
OFF appears on the display.
2. Unplug the power cord.
3. Wearing heat resistant gloves, remove the all
accessories, Top cover (if applicable) feeder, chute,
rear panel and set aside (Figure 1)
BACK PANEL
HEATED LANDING ZONE
(Accessories may be different depending on model number)
®
TOP COVER
FEEDER
CHUTE
Figure 1.
®
4. Facing the front of the unit, move to the right side
panel. Rotate the unit as necessary for access.
5. Unlock the side panel door using a screwdriver,
coin, or similar tool. Open the side panel (Figure 2).
TOP
FRONT
ROLLER
BOTTOM
ROLLER
6. TOP BELT:
Remove tension on the Top Belt by pushing the Top
FRONT Roller IN and UP until it locks into position.
7. BOTTOM BELT:
Remove tension on the Bottom Belt by pushing the
Bottom FRONT Roller IN and DOWN.
8. Rotate the knobs shown in figure 3 half turn.
NOTE: If your unit came with clips attached to
the knobs, remove and discard them
9. Lift up on the tension brackets until it locks in the up
position and does not drop down. Repeat process
for opposite side of unit.
LIFT THIS
BRACKET
1
LOCK
LEVER
FRONT
Figure 2.
KNOB
Figure 3.
P/N 1012999 Rev. A 03/19
SIDE
PANEL
DOOR
CLIP
LOCK LEVER

Advertisement

loading
Need help?

Need help?

Do you have a question about the GST-1H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Antunes GST-1H

  • Page 1 ® ANTUNES www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188 GST BELT REPLACEMENT INSTRUCTIONS (P/N 1012999) 4. Facing the front of the unit, move to the right side WARNING panel. Rotate the unit as necessary for access. Turn the unit off, unplug the power cord and allow the unit to cool down before performing any service or 5.
  • Page 2 ANTUNES www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188 GST-BELT REPLACEMENT INSTRUCTIONS (P/N 1012999) 4. Restore tension on the bottom belt by pushing UP and NOTE: If the brackets will not move, rotate the knobs from Step 8 a half turn until the brackets can be OUT (Figure 2) lifted up.