USING THE CURRENT PROBE

To use the Current Probe, follow these instructions:
1. Connect the 80i-110s Current Probe to the desired input on the measuring
instrument. When the ScopeMeter test tool or an oscilloscope is used, it must
have DC coupled input. When you are using a digital multimeter, use the BNC-
to-banana adapter (PM9081/001) to connect the probe to the input.
2. On the Current Probe, select the least sensitive range (10 mV/A). Ensure that
the green ON-indicator lights. See Figure 4 for selector switch and green ON-
indicator locations.
3. On the Current Probe, rotate the ZERO thumbwheel to adjust the probe
reading to zero. See Figure 4 for the ZERO rotary knob location.
4. Select the appropriate probe sensitivity on your ScopeMeter test tool or
oscilloscope.
5. Clamp the Current Probe around the conductor; be sure that the arrow marked
on the jaw of the Current Probe points toward the correct orientation. (see
Figure 3.)
Figure 3.
Orientation of the Current Probe