Parameter Entry; Program Protection - ABB COPA-XE Instruction Bulletin

Electromagnetic flowmeter with pulsed dc magnetic field excitation
Table of Contents

Advertisement

4.

Parameter Entry

4.1

Program Protection

4.2
Language
4.3
Submenu Primary
4.3.1
Q
for the Meter Size at 10 m/s
maxDN
4.4
Qmax
4.5
Pulse Factor Forward and Reverse
4.6
Pulse Width
4.7
Low Flow Cutoff
4.8
Damping
4.9
Filter (Noise Reduction)
4.10
Density
4.11
System Zero
4.12
Submenu "Units"
4.12.1
Units Qmax
4.12.2
Units Flow Totalizer
4.12.3
User Programmable Units
4.12.3.1
Units Factor
4.12.3.2
Unit Name
4.12.3.3
Programmable Units
4.13
Submenu Alarm
4.13.1
Error Register
4.13.2.
Setting the MAX-Alarm
4.13.3
Setting the MIN-Alarm
4.14
Submenu "Programmable In/Output"
4.14.1
Contact Output Terminals P7/G2
4.14.1.1
General Alarm
4.14.1.2
Empty Pipe
4.14.1.3
Forward/Reverse Direction Signal
4.14.1.4
No Function
4.14.1.5
MAX-Alarm
4.14.1.6
MIN-Alarm
4.14.1.7
MAX/MIN-Alarm
4.14.2
Terminals X1/G2
4.14.2.1
External Zero Return
4.14.2.2
External Totalizer Reset
4.14.2.3
External Totalizer Stop
4.14.2.4
No Function
4.15
Submenu "Current Output"
4.15.1
Current Output
4.15.2
Iout at Alarm
4.16
Submenu "Data Link"
4.16.1
Communication
4.16.2
Instrument Address
4.16.3
Baudrate
4.17
Submenu "Function Test"
4.18
Submenu "Empty Pipe Detector"
4.18.1
Detector on/off
4.18.2
Alarm "Empty Pipe"
4.18.3
Iout for Empty Pipe
4.18.4
Threshold
4.18.5
Adjust "Empty Pipe Detector"
4.19
Submenu "Totalizer"
4.19.1
Reset Totalizer and Overflow Values Fwd., Rev.
4.19.2
Totalizer Function
4.19.2.1
Totalizer Function Standard
4.19.2.2
Totalizer Function Difference Totalizer
4.20
Submenu "Display"
4.20.1
Display 1st Line
4.20.2
Display 2nd Line
4.20.3
1st Display Line Multiplex
Electromagnetic Flowmeter
4.20.4
2nd Display Line Multiplex
4.21
Submenu "Operating Mode"
4.21.1
Operating Mode "Standard/Fast"
4.21.2
Flow Direction
4.21.3
Flow Direction Indicators
4.22
Load Data from External EEPROM
4.23
Store Data in External EEPROM
4.24
Software Version
4.25
TAG-Number
4.26
Service Code Number
4.1
Program Protection
Parameters can be changed after the power has been
turned on only when the program protection is turned off.
There are two procedures for turning the program protection off:
1.
If the Program Protection Code (PP-Code) is set to "0"
(Factory setting), then the program protection can be
turned off by pressing ENTER.
2.
If the Program Protection Code is set to any other value
(1-255), then this number must be entered before the
program protection can be turned off. It is possible to
change the Program Protection Code after the program
protection is turned off.
Prog. Prot. Code
For security reasons the old PP-Code number must be entered
after pressing ENTER before the PP-Code can be changed.
Old PP-Code?
0
After the value has been entered press ENTER.
New PP-Code:
0
Enter the new PP-Code number (1-255) and accept by
pressing ENTER. The newly entered PP-Code is now valid
for turning the program protection off.
Note:
During data entry the values entered are checked
for plausibility and if necessary, rejected, and an
appropriate message displayed.
COPA-XE / MAG-XE
19