9 | Analog and Frequency Inputs
42 / 100
2.
Expand the list of 'I/O Channels' by clicking on '+' in the C 60 Project Tree.
3.
Drag the 'Sensitivity/Offset' analog signal source from the Toolbox and drop it on the
desired analog input channel in the C 60 Project Tree. A 'Sensitivity/Offset Wizard'
opens.
4.
To activate the internal pullup-resistor, check the box. The internal pullup-resistor is
used to get a 5 V signal at the analog channel of the C 60. It allows you to use a push-
button. The fixed value of the internal pullup-resistor is 3010 Ohm. If using an addi-
tional external pullup-resistor, set up the overall resistance.
5.
Click 'Next' when done. The second part of the 'Sensitivity/Offset Wizard' opens.
Physical
(channel)
value
6.
Click 'Next' when done. The third part of the 'Sensitivity/Offset Wizard' opens.
Data_Logger_C_60_Manual
Choose unit
group and unit
of physical value
Enter values
from sensor
datasheet