RPTU Interface Unit

Circuits per PCB:
Interfaces with:
Older Version(s):
The RPTU provides 30 channels for ISDN PRI service.
The RPTU's LEDs indicate a continuous status of its operation (see
page
5-5).
Switches, jumpers, and interface connectors are described in

RPTU Overview

The RPTU provides 30 B channels and 1 D channel. Each RPTU can also use its own D-channel for
control.
The RPTU's in-service bit rate is 2.048 mbps (± 4.6 ppm), but during a maintenance session, the rate
may vary ± 32 ppm.
Extracting the LAYER-1 clock from the ISDN PRI service provider is the most common method used
to synchronise the RPTU PCB and the CT time switch to the public switched telephone network. One
RPTU or RBSU, must extract the clock from the ISDN provider. The selected unit is designated as the
"Primary" timing source in system Programming. In remote cabinet applications, the Primary clock
source PCB must be installed in the Base Cabinet (main location). For more information, refer to
"Timing and Synchronisation" on page

Slot Assignments

Up to nine RPTU PCBs can be installed in a Strata CTX system providing up to 264 PRI lines
(B-channels). If RPTU (PRI) PCBs are installed, the maximum combined PCBs cannot exceed the
eight. The PCBs must be placed in designated slots in each of the cabinets. Refer to
CTX
Configuration,
PCB slot assignments.

RPTU Installation

Before installing a RPTU PCB into a Strata CTX system, refer to
Configuration:
"Strata CTX670 Cabinet Slot Configuration" on Page 1-23
"ISDN PRI Digital Line PCBs" on Page 1-25
To install an RPTU PCB
1. Turn the Strata CTX system power Off.
2. Insert the RPTU (component side facing right) into the appropriate slot (see
Line PCBs" on Page
3. After installing the RPTU, gently pull the PCB outward. If the connectors are properly seated, a
slight resistance is felt.
For cabling information and requirements, refer to
Note
Strata CTX I&M September 2002
30 channels
ISDN PRI
none
5-21.
"ISDN PRI Digital Line PCBs" on Page
1-25) and apply firm, even pressure to ensure proper seating of connectors.
Figure 5-3
Table
5-1.
1-25, for the guidelines regarding RPTU
Chapter 1 – Strata CTX
(mentioned above in slot assignments)
"Cabling" on Page
ISDN Interfaces
and
Table 5-2 on
Chapter 1 – Strata
"ISDN PRI Digital
5-6.
5-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strara ctx100Strara ctx670

Table of Contents