Disposal Vessel With Overfill Sensor (Optional Equipment); Maintenance Of Clean Tank 2 With P63 - BÖWE P25 Instruction Manual

Hide thumbs Also See for P25:
Table of Contents

Advertisement

11
Maintenance

11.5.8 Disposal Vessel with Overfill Sensor (Optional Equipment)

You must check the function of the overfill sensor once a week.
Sequence of the check:
-
Loosen the 2" screwed union
-
Lift the ventilation pipeline
-
The light-emitting diode (LED) on the probe is "green"
-
Now touch the probe at the tip (3 - 5 cm/1.2 - 2.0"); the color of the LED must change from
"green" to "red".
-
The probe is in order
-
Firmly tighten the 2" screwed union again

11.5.9 Maintenance of Clean Tank 2 with P63

To prevent water from collecting in the clean tank, you must run program P63 once a week by to perform
the clean tank maintenance.
Before starting program 63, you must clean the button trap strainer; the cage must be empty.
Program sequence:
All but a few quarts of the solvent are pumped into the cage.
-
Pump out tank 2 into the still.
-
Rinse tank 2, then pump out the rinsing detergent solution into the still
-
Pump the detergent solution from the cage back into tank 2
-
Short drying program.
-